Budapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Environmental Microbiology and Biotechnology Group
Organisation/Data provider's nameBudapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Environmental Microbiology and Biotechnology Group
Name of contact
Dr. Molnár Mónika, Dr. Feigl Viktória
Telephone/fax
+36-1-4632347
Website
Method Hungarian nameSzervesanyag-tartalom: izzítási veszteség 600 Celsius fokon
Method name
Organic matter content:Loss in mass after incineration at 600C
Stage of development
after application
Patent number
MSZ 318/3:1979
Chemical substance group|Typically treated chemical substance
- Not a chemical substance
Detection limit
0.01 %
Measurement limit
100 %
Accuracy (%)
10.00
Reproducibility (%)
10.00
Deviation (%)
10.00
Selectivity
non-selective
Method type
measurement/analytical method
Place of application
In laboratory
Application areas of the method
Contaminant characterisationin in extract
General characterisation of surface water
Characterisation of the effect of technological interventions
Application possiblities of the method
Screening of contaminated environment
Preliminary assessment of contaminated environment
Detailed assessment of contaminated environment
Monitoring of contaminated environment
Technology monitoring
Environmental element/phase the method may be applied to
Saturated soil
Unsaturated (whole) soil
Pore water
Subsurface water
Surface water
Surface water sediment
Leachate
Instrument/equipment needed to perform the measurement
izzítókemence, szárítószekrény, analitikai mérleg (0,0001 g)
Necessary qualification
specialisation not required
Type of laboratory
general analytical laboratory
Purchase price of the equipment
800 - 2.000 Euro
Labour cost/measurement
0 - 2 Euro
Total cost/measurement
4 - 8 Euro
Brief concise description explaining the innovation
Szabványos módszer, nem tartalmaz újdonságot.
Detailed Protocol
105 C szárított mintát lemérjük és 600 C-on tömegállandóságig izzítjuk, majd lemérjük, a kettő közti különbség lesz az izzítási veszteség
Costs
4-low
Time requirement
2-high
Workload requirement
4-low
Equipment, apparata requirement
3-medium
Qualified labour
4-low
Environmental risk and workplace risks
4-low
Environmental reality
4-good
Adequate accuracy
4-good
Reproducibility
4-good
Cost efficiency
5-excellent
Feasibility
4-good
Availability
4-good
Well known
4-good
Strengths
Szinte bármilyen típusú mintára alkalmazható.
Weaknesses
Az eredmény értékelése körültekinést, szakértelmet igényel.
Publications
MSZ 318/3:1979
Location of the application, country
Magyarország
Location of the application, town and/or region
Budapest
Year of application
2008
Application areas
Contaminant characterisationin in extract
Environmental element the method was applied to
Preliminary assessment of contaminated environment
Detailed assessment of contaminated environment
Environmental element/phase the method was applied to
Unsaturated (whole) soil
Datasheet id (original)
250
Creator
Hajdu Csilla
Status
Verified
Adatlap típusaPhysico-chemical assessment methods
Létrehozás
Módosítás