Reduktív lúgosító rendszer

Budapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Environmental Microbiology and Biotechnology Group

Organisation/Data provider's nameBudapest University of Technology and Economics, Department of Applied Biotechnology and Food Science, Environmental Microbiology and Biotechnology Group
Name of contact
Dr. Molnár Mónika, Dr. Feigl Viktória
Telephone/fax
+36-1-4632347
Technology Hungarian nameReduktív lúgosító rendszer
Technology name
Reducing and alcalinity producing system (RAPS)
Country of origin
Anglia
Stage of development
under demonstration
International resources
469 Dollar
Name of the International Programme
CoSTaR, RITA-CT-2003-506069
Contaminant group|Contaminant typically treated
  • Metals, semi-metals and their compounds
  • other metal
Other contaminants
magnézium
Typical initial value
71700 µg/l
Typical final value
57000 µg/l
Contaminant group|Contaminant typically treated
  • Metals, semi-metals and their compounds
  • iron
Typical initial value
50030 µg/l
Typical final value
4940 µg/l
Contaminant group|Contaminant typically treated
  • Other inorganic chemical compounds
  • other inorganic substance
Other contaminants
szulfát
Typical initial value
916000 µg/l
Typical final value
547000 µg/l
Contaminant group|Contaminant typically treated
  • Metals, semi-metals and their compounds
  • manganese
Typical initial value
6670 µg/l
Typical final value
4660 µg/l
Contaminant group|Contaminant typically treated
  • Metals, semi-metals and their compounds
  • aluminium
Typical initial value
28570 µg/l
Typical final value
1660 µg/l
Contaminant group|Contaminant typically treated
  • Metals, semi-metals and their compounds
  • zinc
Typical initial value
1080 µg/l
Typical final value
240 µg/l
Contaminant group|Contaminant typically treated
  • Not a chemical substance
Other contaminants
pH
Typical initial value
5.03 µg/l
Typical final value
7.03 µg/l
Environmental element/phase the method may be applied to
Subsurface water
Technology type
simple
Basis of the technology
Physical- chemical
Biological
Technology description

Savas bányavizek kezelése során a pH-t semlegesíteni, azaz a lúgosságot növelni kell. Ezt a rendszerben lévő mészkő oldódása és a komposztban található szulfátredukáló baktériumok által oxigénmentes környezetben lejátszódó szulfátredukció biztosítja. A fémek, például a vas eltávolítása a szulfát redukcióval egyidejűleg jön létre, a vas(II)ionokból vas-szulfid keletkezik.Az esetleg jelenlévo toxikus fémek is kicsaphatóak szulfidként.
Még az anoxikus rendszerben is vannak olyan területek, ahol aerob körülmények jellemzőek. Ilyen környezetben a fémek oxidálódhatnak és (oxi)hidroxid formában kicsapódnak.

Description of the novelty of the technology

A rendszer passzív, kialakítása után csak ritka gondozást igényel. A tájba tökéletesen illeszkedik. Újdonság a komposzt és a mészkő együttes, kevert alkalmazása a fémek eltávolítására és a pH növelésére.

Remediation technology type
  • biological
  • treatment of groundwater in pond
Other remediation technology
reduktív lúgosító rendszer
Remediation technology from contaminant point of view
immobilisation
Remediation technology from execution point of view
in situ
Technological parameters
Water flux
Contaminant amount
Temperature
pH
Redoxpotential
Other
Other technological parameter

Lúgosság, vezetőképesség

Monitored environmental element
Surface water
Capital costs
40.000 - 200.000 Euro
Specific total costs
no estimation
Costs
3-medium
Time requirement
2-high
Space requirement
3-medium
Workload requirement
3-medium
Equipment, apparata requirement
3-medium
Qualified labour
3-medium
Environmental risk and workplace risks
4-low
Ability to meet the target value
4-high
Environmental efficiency
5-very high
Cost efficiency
4-good
Generation of any recyclable byproduct
no
Generation of any byproduct to be treated
no
Automation/remote control
yes
Feasibility
4-good
Availability
3-average
Well known
2-weak
Strengths

Savas bányavizek tisztítására alkalmas. Természetes energiaforrásokat használ: topográfiai gradiens, mikrobák metabolikus energiája, fotoszintézis, kémiai energia. Jól alkalmazhatóak olyan vizek kezelésére, amelyek bár toxikus fémeket nem tartalmaznak, de esztétikai szempontból problémákat okoz nagy fémtartalmuk. Kevés fenntartást igényelnek, viszonylag olcsók és jól beilleszthetőek a környező tájba, nem egy vízkezelő üzemnek, hanem természetes tónak néznek ki.

Weaknesses

Ritka, de rendszeres kezelést igényel. A vízszint esetleges nagymértékű ingadozása ellen fel kell készülni: árvízvédelmi töltés, zsilip stb. Télen befagyhat.

Possibilities

Kombinált alkalmazása más rendszerekkel.

Threats

A rendszer feltöltődhet a csapadékkal. A természet pl. vízimadarak, ivó állatok hamar birtokba veszik az új vízfelületet, mely által a toxikus anyagok a táplálékláncba kerülhetnek.

Site name
Bowden Close
Location of the application, country
Anglia
Location of the application, town
Durham County
Application stages
Demonstration
Origin of the pollution
szénbányászat
Summary of the charasteristic parameters of application

Az 1950-es években bezárt szénbánya remediálása az 1970-es években megtörtént. 1998-99-ben a meddőhányóról szivárgó vizeket erősen savasnak találták (pH=3-4) nagy Fe, Al és Mn tartalommal. Két RAPS egységet és egy aerob lápot alakítottak ki, melyek egymás után kezelik a csurgalékvizet. A RAPS egységekben lótrágya, szalma és mészkő keverékét alkalmazták.

Publications

Paul L Younger: Passive in-situ remediation techniques for polluted mine drainage: recommendations from the PIRAMID project, Difpolmine Short Course, Budapest, 4-7 July, 2005, előadás

Datasheet id (original)
480
Creator
Feigl Viktória
Status
Verified
Adatlap típusaSoil remediation technology
Létrehozás
Módosítás